PCR TC1000-S



Features : 
* Widely used in molecular biology, clinical diagnosis, criminal investigations, and infectious disease research, etc.
* Provides consistent and uniform sealing accross an entire block.
* Excellent temperature control system.
* Fast heating and cooling rate.
* Intuitive touch-screen user interface.

Specification : 
* Sample capacity : 0.2ml PCR tubes× 96, 1PCR plate 8× 12 or 96 well plate x1
* Heating temperature range : 4 - 99° C
* Lid temperature range : 50 - 110° C
* Temperature display accuracy : 0.1° C
* Temperature accuracy : ± 0.3° C at 55° C
* Temperature uniformity : < 0.3° C at 55° C
* Display : 7 inch, 800 x 480 LED
* Touch operation : Yes
* Power-off protection : Yes


Untuk informasi lebih lanjut dan pemesanan silahkan menghubungi kami :

CV. ALMANDIRI SCIENTIFIC
Jl. Wibawa Mukti II RT 002 RW 04 NO.71
Jatiasih, Bekasi 17425
Tel : 021 9772 9679
Mobile : 0812 9049 9696 / 0812 9124 7778
Pin BB : 295E65C6
Email : sulfan@almandiri.com
Website : www.almandiri.com

Jual Freeze Dryer, Jual Laboratory Freeze Dryer


LABFREEZ INSTRUMENT
Freeze Dryer FD-10-MTP


Features : 

* Microprocessor control
* Environment-friendly, conform to international standard ( CE, ISO) 
* Communication interface & LCD display include drying curve, vacuum, condenser temperature, run time, ambient temperature
* With pre-freezing for samples, widely open condenser, without inner coil
* Large refrigerating capacity and slight noise of Danfoss Compressor
* The pre-cooling shelf can be used as draft tube to accelerate drying speed
* Condenser and the operation panel are made of 304 stainless steel, which is corrosion-resistant and easy to clean
* Transparent bell-cap drying kiln is safe and easy to observe
* Stainless steel sample shelf, the space among common sample tray can be adjusted
* Novel design, small size and simple operation
* For water based sample, the -55° C condenser is the perfect choice with effective cost. For sample containing solvents or with low eutectic points, the -80° C condenser provides maximum performances
* For labs that needs quick turn-around, electric heating defrost is optional
* Nitrogen inflation valve is optional

Specification : 

* Type : 8-port branch manifold Top-press
* Freeze Dry Area : 0.007~ 0.1M2
* Cold Trap Temperature : < -55° C / -80° C ( optional) 
* Ultimate Vacuum : < 10 Pa
* Water Capture Capability : 3~ 4Kg/ 24hr
* Material Tray : Stainless steel sample holder, tray height adjustable, layers free setting, material thickness not more than 10mm, freeze drying time around 24 hours
* Tray Diameter : Ø 180mm x 3
* Material Capacity : 0.7~ 1.2 Litre
* Vials Ø 22mm : 260 pcs
* Vials Ø 16mm : 480 pcs
* Vials Ø 12mm : 920 pcs

Optional Accessories : 
* FD1001 : -80° C Condenser
* FD1002 : RS232 & Software
* FD1003 : Heating element for defrost


Untuk informasi lebih lanjut dan pemesanan silahkan menghubungi kami :

CV. ALMANDIRI SCIENTIFIC
Jl. Wibawa Mukti II RT 002 RW 04 NO.71
Jatiasih, Bekasi 17425
Tel : 021 9772 9679
Mobile : 0812 9049 9696 / 0812 9124 7778
Pin BB : 295E65C6
Email : sulfan@almandiri.com
Website : www.almandiri.com

Selasa, 01 September 2015

Jual Ultrapure Lab Water System

REPHILE BIOSCIENCE
Direct-Pure UP Ultrapure & RO Lab Water System

The Direct-Pure UP Ultrapure & RO Lab Water System is an integrated system that produces ultrapure and reverse osmosis (RO) water from tap water directly. Quality of ultrapure water meets or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.

Features :
 
- Electrical and water compartments are completely segregated, thus safer to operate.
- The fully automated control system contains pre-rinse, RO membrane fouling preventing flush, RO membrane and cartridge life monitoring as well as many other programs for convenient operation.
- The pre-rinsing program starts automatically when a new RO membrane is installed so there is no need for users to set up additional cleaning procedures.
- Two sets of dual-column purification cartridges work sequentially to ensure thorough removal of ions and organics in water.
- The system recirculates automatically every hour to prevent microbial from growing
- Resistivity is measured by a high-precision resistivity meter.
- Users can set water dispensing time for easy water collection.
- The system is equipped with a 30-liter PE tank (upgradable to a 60-liter) and a liquid level sensor.
- A 0.2 μm final filter or ultrafiltration filter (optional) removes final contaminants.
- RephiLe can provide full document support to meet users’ GMP, GLP, FDA and other certification requirements.


Main Application Ultrapure Water :

* HPLC mobile phase preparation
* Preparation of reagent blank solution
* As sample diluents for GC, HPLC, AA, ICP-MS and other analytical techniques
* Preparation of buffer and culture media for mammalian cell culture
* Preparation of molecular biology reagents, etc.


Main Application RO Pure Water :
 
* Glassware cleaning
* Washing machine for glassware
* Water bath water
* Autoclave
* Feed water to laboratory animals


Specification :

a. Feed Water Quality
  • Tap water : Municipal water, TDS < 1000 ppm (2000 μS/cm)
  • Operating temperature : 5~45 ℃
  • Feed water pressure : 15 - 90 psi (1 - 6 bar)
b. Water Production Rate
  • Ultrapure water (Type I) : 1.5 L/min at 25℃
  • RO Water : 10 to 30 L/h at 25℃
c. Product Water Quality
  • RO water conductivity : Typically < 20 μS/cm
  • Resistivity : 18.2 MΩ·cm at 25℃
  • TOC : < 10 ppb (< 5 ppb with a dual wavelength UV lamp)
  •  Particle (> 0.2 μm) : < 1/ml (with a 0.2 μm final filter)
  • Microorganisms : < 1 cfu/ml (with a 0.2 μm final filter)
  • Pyrogens (endotoxins) : < 0.001 Eu/ml (with UF filter)
  • RNase : < 0.01ng/ml(with UF filter)
  • DNase : 4 pg/μL(with UF filter)
d. Dimensions (LxDxH) : 30 x 51 x 48 cm
e. Net Weight : Approx. 25 Kg


Untuk informasi lebih lanjut dan pemesanan silahkan menghubungi kami :

CV. ALMANDIRI SCIENTIFIC
Jl. Wibawa Mukti II RT 002 RW 04 NO.71 Kp. Pedurenan
Jatiasih, Bekasi 17425 - Jawa Barat
Tel : 021 9772 9679
Mobile : 0812 9124 7778 / 0812 9049 9696
Pin BB : 295E65C6
Email : sulfan@almandiri.com
Website : www.almandiri.com

Jual AAS, Jual Atomic Absorption Spectrophotometer, Jual Spektrofotometer Serapan Atom


RAYLEIGH WFX-210 AAS
(Fully Automatic Flame/Graphite Furnace AAS)

Features :
  • The patented flame analysis technique adopting oxygen-rich air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses.
  • Automatic hollow cathode lamp changeover.  The high performance HCL can be used directly.
  • Auto-changeover and position optimization of integrated flame/graphite furnace atomizer.
  • Light-controlled graphite furnace power supplier, adopting FUZZY-PID temperature control technique and dual curve working mode, ensures fast heating, accurate and stable temperature control and good temperature reproducibility.  Temperature auto-correction function provided.
  • Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact.
  • High accuracy and reproducibility of the graphite furnace auto-sampler, realizing fully automation of graphite furnace analysis.
  • Auto-ignition, automatic spectral bandwidth selection.
  • Fully automated wavelength scanning and peaking
  • Automatic setting of Gas flow
  • Perfect safety protection measures, alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction; spray chamber made of explosion-proof material, all-titanium burner and explosion-proof stopper for flame analyses; alarm and protection function to argon pressure deficiency, insufficient cooling water supply, over-heating and over-current etc. in graphite furnace analyses.
  • Adopting large-scale programmable logic array and Inter IC bus technique and highly reliable adapters for electric design.
  • Standard RS-232 serial interface communication
  • Easy and flexible WINDOWS operating system, with multi-windows processing technology to observe the signal profile, the measured results and the calibration curve at the same time.  Various analytical programs, data, signals and graphics can all be stored for later use.
Specification :

* Wavelength range :  190-900nm
* Wavelength accuracy :  Better than ±0.25nm
* Resolution :  Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%
*  Baseline stability : 0.004A/30min
* Background correction : The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
* Lamp turret :  6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.); auto alignment; auto fine adjustment; fully automated scan and peak-picking
* Monochromator : Single beam, Czerny-Turner design grating monochromator
* Grating : 1800 l/mm
* Focal length : 277 mm
* Blazed wavelength : 250 nm
* Spectral bandwidth :  0.1nm, 0.2nm, 0.4nm, 1.2nm, auto-switch over
* Atomizer :  Flame & Graphite Furnace atomizer automatic changeover. Automatic graphite furnace position optimization, automatic flame height setting and horizontal position optimization. Automatic gas flow setting, alarm and automatic protection function for gas leak, abnormal flow, air-pressure deficiency and abnormal flame extinction, automatic ignition.
* Detector : Photomultiplier with high sensitivity and wide spectral range.
* Analytical method : Working Curve Method (1st order and 2nd order fitting) with automatic sensitivity correction; Standard Addition Method.
* Concentration :  Auto-calculation of concentration and content
* Repeatable measurement :  Repeated measurement of up to 99 times, automatic calculation of mean value, standard deviation and relative standard deviation
*  Multi-task functions : Sequential measurement for multi-element determination to the same sample (Max. 6 elements)
* Burner :  10cm single slot all-titanium burner
* Spray chamber : All-plastic spray chamber
* Nebulizer :  High efficiency glass nebulizer with metal sleeve
* Dimension : 107 x 49 x 58 cm (Main Unit)
* Weight : Approx. 140 Kg

Optional Accessories :
* Graphite Furnace System (for analyze in ppb level)
* Autosampler
* Water Hydride Generator (for analyze Arsenic, Mercury, Bismuth, etc)

Complete with :
* PC Desktop (Intel Core i3) with LED Display and Color Printer
* BRAIC Software English Version
* 10 pcs Hollow Cathode Lamp (HCL)
* 10 bottle Standard Solution 1000 mg/l
* Acethylene gas UHP/HP with regulator
* Oxygen gas UHP/HP with regulator
* Oiless Air Compressor
* Stabilizer 3kVA
* Ducting installation (canopy hood, flexible ducting, and exhaust blower fan)

Untuk informasi lebih lanjut dan pemesanan silahkan menghubungi kami :

CV. ALMANDIRI SCIENTIFIC
Jl. Wibawa Mukti II RT 002 RW 04 NO.71 Kp.Pedurenan
 Jatiasih, Bekasi 17425 - Jawa Barat
Tel : 021 9772 9679
Mobile : 0812 9124 7778 / 0812 9049 9696
Pin BB : 295E65C6
Email : sulfan@almandiri.com
Website : www.almandiri.com




Jual UV-Vis Spectrophotometer, Jual Spektro UV-Vis, Jual Spektrofotometer


RAYLEIGH UV-1800
UV-Vis Spectrophotometer

Wavelength Range : 190-1100nm
Spectral Bandwidth : 2nm ( 5nm, 1nm optional) Wavelength Accuracy : ± 0.5nm Wavelength Reproducibility : 0.2nm Photometric Accuracy : ± 0.5% T( 0-100% T) , ± 0.002A( 0-0.5A) , ± 0.004A( 0.5A-1A) Photometric Reproducibility : 0.2% T Working Mode : T, A( -0.33A) , C, E Stray Light : d0.1% T( NaI, 220nm; NaNO2, 340nm) Baseline Flatness : ± 0.002A Stability : d0.002A/ h( at 500nm, after warming up) Noise : ± 0.001A ( at 500nm, after warming up) Detector : Silicon photo-diode Display : 6 inches high light blue LCD Connection Interface : USB, can be integrated with PC / Notebook Power : AC: 220V/ 50Hz, 110V/ 60Hz, 140W Dimensions : 530× 410× 210mm Weight : 18kg

Untuk informasi lebih lanjut dan pemesanan silahkan menghubungi kami :

CV. ALMANDIRI SCIENTIFIC
Jl. Wibawa Mukti II RT 002 RW 04 NO.71 Kp. Pedurenan
Jatiasih, Bekasi 17425 - Jawa Barat
Tel : 021 9772 9679
Mobile : 0812 9124 7778 / 0812 9049 9696
Pin BB : 295E65C6
Email : sulfan@almandiri.com
Website : www.almandiri.com

Jumat, 27 Maret 2015

Jual Gas Chromatography, Jual GC






RAYLEIGH
SP-3400 Gas Chromatography ( GC)

Specification :

* Self-diagnostic Function : Core tests; Automatic tests; Extended tests; Basic tests; Monitor the status of GC continuously. Once finding faults, it will display the information, show the wrong zone and the setting method
* Self-protective Function : Overrun temperature protection; Short circuit hint; TCD filament protection; FID flameout hint
* Injectors : On-Column Injector for Packed Column; Flash Vaporization Injector for Packed Column; Automatic or manual gas inject valve; Headspace sampler; Thermal desorption system; Split/ Splitless Capillary Injector
* Detectors : TCD + FID
* Programming of Detector : Each of detectors has 5-ramp programmable time control, output-signal, attenuation range, and polarity can be changed automatically
* Temp. Range Column Oven : Ambient temperature to 420° C
* Cooling Time : 250° C to 50° C in 5 minutes
* Sensitivity Detector-TCD : e12000mv Ï mL/ mg ( for butane)
* Linear Range : 105
* Filament Protection : If He or H2 carrier gas flow in the detector cell is off for 4 minutes, filament power automatically shuts off
* Max. Temperature Detector FID : 420° C
* Minimum Detectivity : d1.3× 10-12g/ s ( n-C16)
* Flameout Hint : Monitoring the status of GC continuously, after being turned on

Complete with :

* PC Desktop Branded with LCD Display 18.5 " and others support equipments
* Price FOB Jakarta
* Price quoted include Installation & Training Fee

 